+44 1929 423 222 info@showcad.com

The X-Net 8 has an inexplicably complicated switch setting. In this article I do my best to explain it.

Image

The possible addresses are in the range 2.39.2.4 to 2.39.2.250. Each address setting occupies 2 address slots. So, for example, Sw1 = 1, Sw2 = 3, Sw3 = 0 corresponds to 2.39.2.4 to 2.39.2.5.

It is important to note that the address change does not take affect until the X-Net interface is powered off and on.

The address range below is that of the least significant IP address field.

Address rangeSw1Sw2Sw3 
4 thru 23130 thru 9 
24 thru 43140 thru 9 
44 thru 63150 thru 9 
64 thru 83160 thru 9 
84 thru 103170 thru 9 
104 thru 123180 thru 9 
124 thru 143190 thru 9 
144 thru 163200 thru 9 
164 thru 183210 thru 9 
184 thru 203220 thru 9 
200 thru 219100 thru 9 
220 thru 239110 thru 9 
240 thru 250120 thru 5